- Prospective cadaveric study of 8 embalmed adult cadavers receiving 12 ultrasound-guided methylene blue injections into T3-4 or T7-8 intertransverse process spaces.
- Compared 10 mL with 20 mL injection volumes, with 6 injections per volume group.
- Paravertebral spread occurred in 11 of 12 injections, and multilevel (≥3 level) epidural spread occurred in 3 of 6 with 20 mL versus 0 of 6 with 10 mL, though median spread did not differ significantly between volumes.
- The authors conclude the intertransverse and epidural spaces are anatomically continuous, and suggest larger volumes may raise the risk of sympathectomy-related effects such as hypotension.
Regional
Research from anesthesiology, pain and critical care journals, sourced from PubMed.
Sorted by publication date, not import date. Recent filters exclude papers with only a publication year; find those under All years.
AI-generated abstract summaries can contain errors. Verify findings against the original paper before applying them to patient care.
Last successful paper check: 16 Nov 2026 17:18 UTC.
0 newly discovered papers saved; these are not necessarily published today.
2 papers awaiting AI summaries. Summary processing had an error; paper-fetch status is separate.
Background checks run while the server is active. This does not guarantee a daily run if hosting sleeps.
2 papers awaiting AI summaries. Summary processing had an error; paper-fetch status is separate.
Background checks run while the server is active. This does not guarantee a daily run if hosting sleeps.
- In situ simulation study with 38 staff across 8 simulated operating room local anesthetic systemic toxicity crises, with video recordings analyzed for latent safety threats.
- Latent threats were coded by clinical phase and by work-system factors using a modified SEIPS framework; no comparator group was included.
- Of 183 latent threats identified, 90 (49%) occurred during Management, and Environment (30.1%) and Organization (29.5%) were the most common factors.
- The most common themes were Poor Physical Layout (23.5%) and Role Allocation Deficiencies (23%), and the authors conclude that system redesign, not only clinician education, is needed.