- Pragmatic multicentre randomised trial of 1001 adult surgical patients, with tracheal intubation performed by anaesthesia residents under consultant supervision.
- Patients were randomised to videolaryngoscopy (n=501) or direct laryngoscopy (n=500) for the initial intubation attempt.
- First-attempt success was 79.2% with videolaryngoscopy versus 70.2% with direct laryngoscopy (absolute risk difference 9.0%, 95% CI 3.7-14.4%, p<0.001).
- Videolaryngoscopy also improved glottic view and reduced operator-reported difficulty and procedural complications, with no clinically meaningful difference in intubation time or adjunct device use.
Airway
Research from anesthesiology, pain and critical care journals, sourced from PubMed.
Sorted by publication date, not import date. Recent filters exclude papers with only a publication year; find those under All years.
AI-generated abstract summaries can contain errors. Verify findings against the original paper before applying them to patient care.
Last successful paper check: 16 Nov 2026 17:18 UTC.
0 newly discovered papers saved; these are not necessarily published today.
2 papers awaiting AI summaries. Summary processing had an error; paper-fetch status is separate.
Background checks run while the server is active. This does not guarantee a daily run if hosting sleeps.
2 papers awaiting AI summaries. Summary processing had an error; paper-fetch status is separate.
Background checks run while the server is active. This does not guarantee a daily run if hosting sleeps.
- Single-centre randomized controlled trial of 62 adults in Xi'an, China, undergoing elective unilateral VATS, allocated 1:1 to lateral or supine VDLT intubation.
- Compared video double-lumen tube intubation in a modified lateral position with conventional supine intubation, with operators unblinded and outcome data collectors blinded.
- In-room to cut time was shorter with lateral intubation, 18.1 vs 31.1 min, mean difference -13.0 min (95% CI -14.4 to -11.6; P < 0.001).
- Malpositioning was 1/31 versus 15/31 and sore throat within 48 h was 9/31 versus 18/31, though secondary analyses were exploratory.
- Multicentre randomised trial of 400 children aged 2 to under 7 years undergoing adenotonsillectomy at four tertiary hospitals in China.
- Children were randomised 1:1 to ventilation with a laryngeal mask airway or an endotracheal tube.
- Any perioperative respiratory adverse event occurred in 22.5% of the LMA group versus 57.5% of the ETT group (absolute risk difference -35.0 points, 95% CI -43.5 to -25.7; P<0.001).
- The authors conclude that LMA ventilation by experienced anaesthesiologists produced fewer respiratory adverse events, and neither group had serious adverse events.
- Randomized crossover trial of 35 experienced anesthesiologists intubating a high-fidelity manikin with normal, locked-jaw, and rigid-neck simulated airways.
- Compared Macintosh direct laryngoscopy with C-MAC and King Vision videolaryngoscopes, using surface electromyography of upper limb muscle activity as the primary outcome.
- Direct laryngoscopy produced higher brachioradialis activity than C-MAC in all three scenarios, e.g., 18 vs 12 µV with locked jaw (MD 6 µV; 95% CI 1 to 11; P = 0.02).
- King Vision had the highest NASA-TLX workload, and the authors concluded C-MAC gave the most favourable balance of muscle strain, workload and first-attempt success.
- Prospective randomized controlled trial of 254 children aged 3-9 years undergoing elective adenotonsillectomy.
- Children were intubated with a room-temperature polyvinyl chloride endotracheal tube or one softened and pre-warmed to 37°C.
- Overall perioperative respiratory adverse events were 14.1% with warmed tubes versus 24.6% with room-temperature tubes (p = 0.039), with lower laryngospasm and postoperative coughing.
- Room-temperature tube use was an independent predictor (adjusted OR 2.29, 95% CI 1.16-4.54); the authors call for multicenter confirmation.
- Randomized, assessor-blinded trial in 68 tracheostomized adults with neurologic disorders at one rehabilitation department, 34 per group.
- Both groups received airway clearance techniques with conventional treatment for 6 weeks; the experimental group also received abdominal electrical stimulation.
- Decannulation success was 93.3% with stimulation versus 73.3% in controls (OR 5.070, 95% CI 1.41-18.24, p = 0.013), and peak involuntary cough flow was higher (mean difference 39.433 L/min, 95% CI 28.83-50.04, p < 0.001).
- Infection scores and resting diaphragm mobility did not differ between groups, so the authors report benefit for cough, abdominal muscle thickness and decannulation only.
- Randomized crossover trial in 32 mechanically ventilated children aged 1 month to 18 years who completed both 24-hour monitoring phases.
- Continuous automated cuff pressure regulation targeting 15-25 cmH2O was compared with intermittent manual adjustment by bedside nurses under a predefined protocol.
- Low-pressure episodes (<15 cmH2O) occurred in 12.7% with manual monitoring versus 1.3% with automated (p<0.001), and time outside target fell from 118 to 10 hours.
- Nursing workload was lower with automation (0.08 vs 3.65 h), and the authors conclude automated control should be preferred to enhance airway safety.