- Secondary analysis of data from a randomized trial, with 50 cardiac surgery patients propensity-matched 1:20 to 989 historic institutional patients receiving standard care.
- The comparison was continuous serratus anterior plane catheters versus standard care, with matching on age, sex, smoking, surgery type and pre-existing respiratory disease.
- Pneumothorax occurred more often with catheters (12% vs 3%; OR 5.3; 95% CI 2.1 to 13.6; P < 0.001), while ICU readmission, ventilation and length of stay did not differ.
- The authors found the catheter group had more pneumothorax but note causality is unclear, possibly reflecting trial monitoring differences and baseline population risk.
Cardiac
Research from anesthesiology, pain and critical care journals, sourced from PubMed.
Sorted by publication date, not import date. Recent filters exclude papers with only a publication year; find those under All years.
AI-generated abstract summaries can contain errors. Verify findings against the original paper before applying them to patient care.
Last successful paper check: 16 Nov 2026 17:18 UTC.
0 newly discovered papers saved; these are not necessarily published today.
2 papers awaiting AI summaries. Summary processing had an error; paper-fetch status is separate.
Background checks run while the server is active. This does not guarantee a daily run if hosting sleeps.
2 papers awaiting AI summaries. Summary processing had an error; paper-fetch status is separate.
Background checks run while the server is active. This does not guarantee a daily run if hosting sleeps.
- Single-centre prospective feasibility pilot of 60 adults undergoing cardiac surgery, drawn from 506 screened patients.
- Novice-performed lung ultrasound was compared with chest radiography, using expert ultrasound or senior-radiologist-reviewed radiography as the reference standard.
- Novice lung ultrasound identified 18/19 pneumothoraces (94.7%) versus 13/19 (68.4%) for chest radiography, with NPV 97.6% and kappa 0.97; no confidence intervals were reported.
- Protocol adherence was 98.3% and image quality was sufficient in 96.7%; the authors call for larger, fully powered studies.
- Observational cohort of 440 adults with severe cardiogenic shock on VA ECMO at six Dutch hospitals, 2018 to 2024.
- Cumulative inotropic exposure, the area under the curve of a standardized inotropic score, was analyzed against outcomes with joint modeling.
- Higher cumulative exposure was associated with ECMO weaning failure (HR 1.04; 95% CI 1.00-1.07) and 30-day mortality (HR 1.04; 95% CI 1.01-1.08).
- Inotrope use stayed largely unchanged after ECMO initiation, and higher exposure was also linked to arrhythmias (HR 1.05; 95% CI 1.01-1.08).
- This multicenter observational registry study included 379 mechanically ventilated adults with shock across 23 hospitals, and 96 (25.3%) had TELUS added to resuscitative TEE.
- Operator-reported identification of shock etiology was higher with TELUS plus TEE than with TEE alone (86.5% vs. 75.3%).
- The etiology difference was significant (OR 1.95, 95% CI 1.02-3.72, p = 0.04), but the management change difference was not (78.1% vs. 71.7%; OR 1.40, 95% CI 0.82-2.41, p = 0.22).
- TELUS added a longer median procedure time (21.5 vs. 19.0 min, p = 0.01), complications were rare and similar, and the authors call for prospective studies with patient-centered outcomes.